BMDDH - HIGH SPEED ERADICATOR 601 PT A

  • MSDS: BMDDH
  • Manufacturer: MICHLIN DIAZO PRODUCTS CORP
  • Product Name: HIGH SPEED ERADICATOR 601 PT A
  • National Stock Number: 7510-00N026845
Product Identification

Product ID:HIGH SPEED ERADICATOR 601 PT A
MSDS Date:06/16/1989
FSC:7510
NIIN:00N026845
MSDS Number: BMDDH

Responsible Party
MICHLIN DIAZO PRODUCTS CORP
10501 HAGGERTY ST
DEARBORNE, MI 48126
US

Emergency Phone: 313-846-5700;800-424-9300(CHEMTREC)

Info Phone: 800-521-3240; 313-846-5700

Preparer: ERIC MACHLAS

Cage: 8Y149

Contractor
MICHLIN DIAZO PRODUCTS CORP
DEARBORN, MI 48126 US

Telephone: 800-255-3924

Cage: 8Y149

Ingredients

HYDROCHLORIC ACID

CAS: 7647-01-0

RTECS: MW4025000

Fraction By Weight: 0.2%

OSHA PEL 5 PPM, C

ACGIH TLV: 5 PPM, C

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


FORMALDEHYDE (SARA III)

CAS: 50-00-0

RTECS: LP8925000

Fraction By Weight: 0.05%

OSHA PEL SEE 1910.1048

ACGIH TLV: C 0.3 PPM; A2; 9293

EPA Report Quantity: 100 LBS

DOT Report Quantity: 100 LBS

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: NOT APPLICABLE.CHRONIC: IN VERY
HIGH CONCENTRATIONS MAY CAUSE HEADACHE, CONFUSION, NAUSEA.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHAL: REMOVE TO FRESH AIR. IF NOT BREATHING, GIVE ARTIFICIAL
RESPIRATION. KEEP PATIENT WARM AND AT REST. OBTAIN MEDICAL
ATTENTION IMMEDIATELY. SKIN: FLUSH WITH ABUNDANCE OF WATER, REMOVE
CONTAMINATED CLOTHING. EYE: FLUSH WITH WATER FOR ATLEAST 15
MINUTES; IF IRRITATION PERSISTS, CALL MD. INGEST: INDUCE VOMITING;
CALL MD OR POISON CONTROL CENTER.

Fire Fighting

Extinguishing Media:WATER, CO*2, OR CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP
.NOT CONSIDERED A PRIMARY FIRE HAZ, BUT CARE SHOULD BE TAKEN TO
AVOID EXPOS TO LIQ PROD INVOLVED (SUPP DATA)
Unusual Fire/Explosion Hazard:IF SUBSTANTIAL QUANTITIES ARE INVOLVED,
USE NIOSH/MSHA APPROVED SCBA.

Accidental Release

Spill Release Procedures:ABSORB WITH EARTH, SAND, OR INERT MATERIAL AND
DISPOSE OF WITH SOLID WASTE I/A/W LOCAL, STATE OR FEDERAL
REGULATIONS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:HANDLE WITH CARE. STORE IN DRY,
WELL-VENTILATED AREA AWAY FROM INCOMPATIBLE MATERIALS. PROTECT
AGAINST PHYSICAL DAMAGE.
Other Precautions:KEEP OUT OF DIRECT SUNLIGHT AND AWAY FROM HEAT
SOURCES.

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED SCBA (FOR LARGE SPILLS).
Ventilation:LOCAL EXHAUST VENTILATION REQUIRED WHEN NECESSARY TO COMPLY
WITH ANY ESTABLISHED OSHA THRESHOLD LIMIT.
Protective Gloves:NEOPRENE (CHEMICAL RESISTANT) GLOVES.
Eye Protection:CHEM WORK GOG & FULL LGTH FSHLD .
Other Protective Equipment:WEAR RESISTANT CLOTHING & BOOTS. EYEWASH
STATION IN AREA RECOMMENDED.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRE FIGHT PROC: IN FIRE. (WHEN LARGE QUANTITIES ARE INVOLVED).
EVACUATE AREA OF UNPROTECTED PERSONNEL.

Chemical Properties

HCC:C1
Boiling Pt:B.P. Text:100F,38C
Spec Gravity:APPROX 1.045
Evaporation Rate & Reference:APPROX 1 (WATER=1)
Solubility in Water:COMPLETE
Appearance and Odor:GREEN LIQUID; NO APPARENT ODOR.

Stability

Stability Indicator/Materials to Avoid:NO
STRONG ACIDS, BASES, OXIDIZERS.
Stability Condition to Avoid:OPEN FLAME OR IGNITION SOURCES.
Hazardous Decomposition Products:HYDROGEN CHLORIDE GAS.

Disposal

Waste Disposal Methods:DISPOSE OF I/A/W LOCAL, STATE AND FEDERAL
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,